The article “A comparison of near-and mid-infrared band reflectography in the diagnostics of artwork” by Gavrilov, D.; Kais, C.; Maeva, E.; and Maev, R. (2010) addresses the use of advanced scientific techniques in the conservation and preservation of artworks, specifically in the identification of defects and alterations beneath the surface of paintings. The study focuses on comparing the effectiveness of near-infrared (NIR) reflectography and mid-infrared thermography, exploring methods such as pulse thermography (PT), pulse phase thermography (PPT), and principal component thermography (PCT).
NIR, which uses electromagnetic waves in the range of 0.7-1.1 µm, allows penetration of opaque paint layers and is useful for identifying pentimenti (changes of mind), retouched regions, and alterations in signatures that may indicate forgeries. On the other hand, thermography in the mid-infrared range (3-5 µm) is based on monitoring surface temperature to detect subsurface defects. PT, PPT, and PCT enhance sensitivity by identifying and visualizing defects through the analysis of temperature distributions following heat pulse application.
The work provides a theoretical framework on the multilayer structure of paintings, noting that these often consist of a support (wood, canvas, metal), a priming layer for the paint, and a protective varnish. Over time, these layers may undergo degradation, such as delamination, especially due to differential contraction of materials during drying, which can go unnoticed until the damage is irreversible.
In the experimental practice, the authors used a Fujifilm S3 Pro UVIR near-infrared camera with a Wratten 87 NIR filter for NIR reflectography, and a FLIR SC4000 thermal camera for mid-infrared thermography. Samples of canvas with pentimenti, wooden panels with delaminations, and oil paintings were analyzed. The results showed that NIR was effective in locating pentimenti and preparatory sketches, while thermography was more sensitive to subsurface defects such as delaminations in wood.
Particularly, PT and PCT proved efficient for visualizing the structure and defects in wood. PT was useful for detecting thermal anomalies, while PCT produced high-quality images, revealing details not visible with conventional methods. In contrast, PPT presented noisy images that were difficult to interpret in some cases.
In a test with an oil painting, NIR illuminated a retouched region and PT revealed a hidden detail (a cross on the subject’s neck), evidencing thermal differences due to different pigments. NIR also helped identify preliminary sketches in another painting, suggesting authenticity. In the case of a wooden iconography, PT allowed visualization of delaminations and structural details not visible with other methods.
In summary, the study concludes that both NIR and thermography techniques (especially PPT and PCT) are complementary tools in the diagnosis of artworks. NIR is ideal for locating pentimenti, while thermography is more effective for detecting structural defects and foreign materials beneath the paint surface.