Umbrales de diferencia de color en cerámicas dentales

0
296

The article by Ghinea et al. titled “Color difference thresholds in dental ceramics,” published in January 2010, explores the perceptibility and acceptability thresholds in dental ceramic materials using the CIELAB and CIEDE2000 color difference formulas. The study employs a novel Takagi-Sugeno-Kang (TSK) fuzzy approximation approach alongside traditional methods to determine these thresholds.

The main objective of the study was to determine the thresholds at which color differences in dental ceramics are perceptible and acceptable to observers. The authors used a panel of 13 observers who made independent judgments on the perceptibility and acceptability of 105 pairs of ceramic disks. These disks had color differences ranging from 0.10 to 9.91 according to the CIEDE2000 color difference formula. The ceramic disks used in the study were manufactured with mixtures of various opaque powders and met a range of L, a, and b* color coordinates similar to those of central and lateral incisors and canines.

The SpectraScan PR-704 spectroradiometer was used to measure the spectral reflectance of the ceramic disks, simulating viewing conditions with light similar to the CIE standard illuminant D65 in a VeriVide CAC60 viewing booth. The disks were measured against a black Munsell background, simulating the translucency of teeth and the dark environment of the oral cavity.

The acceptability and perceptibility thresholds obtained with the S-shaped fitting procedure and the TSK Fuzzy Approximation model showed differences. For the perceptibility threshold, the fitted CIEDE2000 values were DE00 = 1.30 (S-curve) and 1.25 (fuzzy TSK), while for CIELAB they were DEab = 1.80 and 1.74, respectively. For the acceptability threshold, the fitted CIEDE2000 values were DE00 = 2.25 (S-curve) and 2.23 (fuzzy TSK), and for CIELAB they were DEab = 3.46 and 3.48, respectively .

The results indicated that the CIEDE2000 color difference formula provides a better fit than the CIELAB formula for evaluating color difference thresholds in dental ceramic materials. Additionally, a statistically significant difference was observed between the perceptibility and acceptability thresholds, where perceptibility thresholds were typically lower than acceptability thresholds, which is consistent with previous studies .

The study also demonstrated that the TSK fuzzy approximation method, although more complex, offered a slight improvement in curve fitting accuracy compared to traditional S-curve methods. These findings support the continued use of the TSK Fuzzy model as a recommended methodology for colorimetric data in dentistry, providing a more precise correlation between visual judgments and instrumental color difference values .

Finally, the authors suggest that future research should continue exploring and refining the weighting functions of CIEDE2000, as this could lead to an even greater correlation with visual judgments, thereby improving the clinical interpretation of color differences in dentistry .

Check on the publisher’s website