The article “Practical Scanner Tests Based on OECF and SFR Measurements” written by Dietmar Wueller and Christian Loebich in 2001 addresses the quality assessment of scanners, a crucial aspect that is often manipulated for marketing purposes. The authors point out that technical specifications, such as scanning resolution and color depth, often do not provide a clear view of the actual image quality that a scanner can produce. At the request of German photography and computer magazines, they developed an evaluation method based on ISO standards developed for digital cameras, adapting them to the specific characteristics of scanners.
The article identifies four main parameters that influence the image quality of a scanner: resolution, which measures the ability to capture fine details; dynamic range, which is the difference between the lightest and darkest areas of an original that show significantly resolved details; noise, which affects quality in areas of homogeneous colors; and color reproduction quality, although the latter is not discussed in depth in the document.
Developing appropriate test charts was a crucial step to measure these characteristics. A test chart must be made of a material similar to that of the original to avoid artifacts that could influence measurements. Charts capable of providing detailed structures and high contrasts were needed, combined with a grayscale to determine dynamic range and noise. In developing their method, the authors managed to produce suitable reflective test charts for scanning resolutions up to 3000 ppi from graphic art paper.
To measure resolution, both visual analysis with test charts from the U.S. Air Force (USAF) and the Spatial Frequency Response (SFR) method were used. Although both methods provide similar results, the SFR method is more precise due to the elimination of aliasing artifacts, especially in scanners where defocused sharpening can be disabled. Additionally, the SFR method also allows measuring the scanner’s color misalignment.
Regarding dynamic range, the authors defined a possible standardization as the difference between the minimum unclipped density of an original and the maximum reproducible density with an adequate signal-to-noise ratio. To measure it according to this definition, they adjusted the scanner software’s gamma curve and automatically analyzed the gray patches using an Adobe Photoshop plugin developed by themselves.
In noise measurement, difficulties were encountered due to the granular structure of the photographic material used. This problem is more pronounced in lighter patches and at higher resolutions. Despite this drawback, the granular structure seems to have less influence on dynamic range measurements. The results obtained are consistent with the visual analysis of scanned grayscale scales and test images.
In conclusion, the article highlights the need to standardize various terms and procedures to avoid misuse in marketing aspects and provide a more accurate and practical evaluation of scanner quality. These efforts also aim to make the disclosure of these parameters by manufacturers more mandatory, to offer users a better understanding of scanner quality.