The article “Quantitative Assessment of Artificial Light Sources for the Best Fit to Standard Illuminant D65” by A. Berger and D. Strocka, published in February 1973, proposes a quantitative method to evaluate artificial light sources in relation to their fit to the standard illuminant D65. The need for this evaluation arose when the International Commission on Illumination (CIE) recommended replacing the illuminant C standard with phases of the D illuminant, specifically D65, to represent average daylight. The irradiance distribution of D65 spans from 300 nm to 830 nm, necessary for the colorimetry of fluorescent and non-fluorescent samples.
The method proposed by Berger and Strocka uses the metamerism index of several pairs of metameric samples to evaluate the correspondence of the light source with D65 in the visible range (300-700 nm), and the fluorescence intensity of a white sample in the ultraviolet range for the same purpose. This evaluation is crucial to ensure that color measurement or matching under artificial light reproduces what would be seen in daylight.
The paper compares its method with previously published criteria, highlighting the British standard BS 950, which establishes that lamps must have chromaticity within a dodecagon on the chromaticity diagram. Other methods discussed, such as Wyszecki’s, evaluate the deviation of the irradiance distribution relative to D65 using various indices: the root mean square deviation, the mean absolute deviation, and a weighted N index using the CIE 1964 uniform color space.
Berger and Strocka performed their calculations with four different color difference formulas to establish the mean metamerism index: Adams-Nickerson-Stultz (ANS), Friele-MacAdam-Chickering (FMC-II), CIE-UCS of 1964, and specific situations such as 10° standard observers. The results indicated that some lamps deemed good according to ANS did not meet the BS 950 criterion, and they suggested that the adjusted metamerism index may be a reasonable tolerance for a good artificial light source.
The evaluation in the ultraviolet range proved to be independent of the color difference formula and the observer, establishing that fluorescent samples must be properly evaluated to ensure their suitability under artificial light. It was also verified that the fluorescence evaluation is a valid measure of the ultraviolet irradiance distribution of the light source.
The study concludes that the proposed method provides meaningful data when comparing various artificial light sources and appears suitable for use in evaluation standards. The ability of a light source to correspond with the standard illuminant D65 is fundamental for accurate colorimetry and color reproduction under artificial lighting conditions.
