El uso adecuado de los índices de metamerismo

0
433

The article by Roy S. Berns, “The Proper Use of Indices of Metamerism”, published in December 2008, addresses a fundamental issue in color science: the evaluation of the quality of color matching using indices of metamerism. Metamerism refers to the phenomenon in which two colors may appear identical under certain lighting conditions but different under others. Metamerism indices allow measuring the quality of this matching under different conditions, providing vital information for industries that depend on precise color control.

Berns distinguishes between two main types of metamerism indices: general, based on spectra, and special, based on colorimetry. General indices do not require parametric correction and are calculated directly from the spectral data of the materials. In contrast, special indices depend on obtaining an exact colorimetric match through parametric corrections before their calculation, which may include spectral or colorimetric adjustments.

The article highlights the importance of correctly interpreting metamerism indices, as these can be misleading if color differences under reference conditions are not adequately considered. A low metamerism index combined with a large color difference under the reference condition leads to a different interpretation than a high metamerism index with a small color difference under the same condition. Berns illustrates this issue through examples using artist paints in blue, yellow, and magenta colors combined to match a spectrally non-selective gray.

Berns emphasizes that special metamerism indices should be calculated only when color differences under the reference condition are small, suggesting a threshold, for example, ΔEab ≤ 5 (a measure of color difference). Outside this range, the indices may lead to misinterpretations, underscoring the limitation of these indices when the reference difference is appreciable. This point is exemplified with the use of various techniques in optimizing parametric and spectral adjustments to minimize metamerism.

Furthermore, the author criticizes the practice of evaluating color matches based exclusively on indices without considering the visualization of spectra. This criticism is supported by the evaluation of results that, in his opinion, do not adequately reflect human visual perception. The argument is reinforced with a recent study on instrumental matching criteria where it is concluded that viewing spectral graphs along with indices is essential for an accurate and comprehensive evaluation.

Through the use of cases and examples, Berns argues that the combination of spectral and colorimetric metrics can optimize the evaluation of metamerism, but stresses that indices must be used within a context where color differences under reference conditions are relevant and interpretable. This profound technical and methodological insight provides clarity on when and how metamerism indices should be applied to avoid errors and ensure accuracy in color quality control.

Review on the publisher’s website