The article “Determination of the Contrast and Modulation Transfer Functions for High Resolution Imaging of Individual Atoms” by Gabriello Presenza-Pitman aims to establish precise methods to measure the resolution of high-resolution optical imaging systems, with the purpose of improving the observation of individual atoms in an optical lattice. This work relies on two approaches: the contrast transfer function (CTF) and the modulation transfer function (MTF).
The CTF is determined using square wave patterns of different spatial frequencies. By capturing images of these patterns and measuring their contrast, it is possible to evaluate how different frequencies affect image quality. In the study, the CTF results for blue light (405 nm) and red light (700 nm) showed qualitatively different behaviors: the blue curve drops rapidly at low spatial frequencies and then levels off, while the red curve follows a more gradual decay typical of a diffraction-limited system. This discrepancy could be attributed to the quality of the objective used, which is better corrected for aberrations at green and red wavelengths than at blue.
On the other hand, the MTF is obtained using the slanted-edge method, which involves capturing an image of an inclined silicon edge. This approach allows the calculation of the edge spread function (ESF) and, by numerically differentiating it, the line spread function (LSF) is obtained, which is then transformed via the fast Fourier transform (FFT) to obtain the MTF. This method is useful because it provides a more comprehensive sampling of the imaging system than using individual sinusoidal patterns.
In the results, it was found that the resolutions calculated for blue and red light, using a 200 μm sapphire window, were approximately 0.61 μm and 0.65 μm, respectively. It was highlighted that the MTF results with a sapphire window showed a steeper decline at low spatial frequencies compared to the absence of such a window, indicating a slightly worse resolution when using the sapphire window due to the introduction of optical aberrations.
Another relevant observation was the presence of a “hump feature” in the MTF graph when observed at a specific numerical aperture (0.43), which is inconsistent with a diffraction-limited system. This suggests the possible presence of spherical aberration, which could be “blocked” by the iris when the diameter is reduced, cutting off the high-angle light rays near the edges of the objective lenses.
Furthermore, experiments were conducted with different numerical apertures, revealing that a smaller numerical aperture results in a faster decrease in modulation and, therefore, worse resolution. These tests showed that closing the condenser diaphragm increases contrast and resolution, due to the elimination of higher light angles and the reduction of present optical aberrations.
In summary, Presenza-Pitman’s article evaluates and compares different methods to determine the contrast and modulation transfer functions in high-resolution optical imaging systems, providing a detailed insight into how different conditions affect image quality and highlighting the importance of optical corrections and adjustments in numerical aperture to improve resolution in the observation of individual atoms.