Color metamerism and the structure of illuminant space

0
384

The article “Color metamerism and the structure of illuminant space” by Akbarinia and Gegenfurtner examines the phenomenon of metamerism, in which two surfaces with different reflectance spectra can appear the same color under one light source but different under another. This phenomenon, known as metamer mismatch, presents significant challenges for visual perception, especially in relation to color constancy.

The authors collected an extensive set of 11,302 reflectance spectra from various natural and man-made surfaces. These surfaces were examined under 27 different types of natural and artificial illuminations. The reflectance spectra, illuminations, and cone fundamentals used are only estimates and, therefore, may be susceptible to measurement errors.

The study determined perceived color differences using the CIE ΔE2000 metric in the CIE Lab* color space, considering different thresholds representing perceptual discriminability. If the color difference of a pair of reflectance spectra is less than a low threshold under one illuminant (perceptually indistinguishable colors) and greater than a high threshold under another illuminant (perceptually distinguishable colors), that pair is considered a metamer. If the color difference is less than the low threshold under both illuminants, that pair is considered an isomer, indicating that the original reflectance spectra of both surfaces are nearly identical.

The findings indicate that metameric pairs are relatively infrequent, but when they occur, perceptual color differences can be significant depending on the conditions. For example, under the illuminant pair “Prime-Street Lamp,” the ΔE can increase from a value less than 0.5 to one greater than 20. Such large differences never occurred when comparing two natural lights. This study found that there is a reliable and systematic structure in the representation of illuminants using non-metric multidimensional scaling (MDS) techniques. This representation allows characterizing the qualities of new lamps with respect to metamerism.

Furthermore, the analysis identified that metameric pairs, although rare, could represent large perceptual color changes under certain pairs of illuminants. For example, under the pair “D65–D75,” no cases were found where ΔE is less than 0.5 under one illuminant and greater than 1.5 under another. In contrast, under “Prime–Street Lamp,” there were approximately 30 incidents of such magnitude of difference.

The interpretation of these results is subject to several factors such as the value used to estimate the just noticeable color difference, the similarity in the set of illuminants, and the variation of reflectance spectra in the dataset. Despite this, the results demonstrate that metamerism is infrequent in most scenarios investigated.

Review on the publisher’s website