An introduction to the Fourier transform: relationship to MRI

0
445

The article titled “An Introduction to the Fourier Transform: Relationship to MRI” by Gallagher, Thomas A.; Nemeth, Alexander J.; and Hacein-Bey, Lotfi, published in May 2008, explores the fundamental application of the Fourier Transform (FT) in the field of magnetic resonance imaging (MRI). The text develops how the FT is a key mathematical tool for decomposing complex signals, translating these into more manageable and essential terms of frequencies and amplitudes for producing detailed and useful images in MRI.

The central premise is that a complex digitized signal, collected during an MRI scan, can be decomposed and organized in the space known as k-space. Here, the Fourier Transform plays a crucial role in resolving the frequency and amplitude information contained in these signals, ultimately allowing the creation of an image through the inverse Fourier transform. Each pixel in k-space, when inversely transformed, contributes a specific spatial frequency to the complete image, all without losing information in the transformation process.

The article also addresses how different methods of activating phase and frequency encoding gradients can creatively influence the way we fill k-space. For example, one strategy may focus on areas of high signal-to-noise ratio in the center of k-space, ignoring regions of low signal-to-noise ratio to optimize acquisition time. This technique often uses the complex conjugate symmetry property of the FT to reduce acquisition time by half by acquiring only half of k-space and generating a mirror image of the other half.

The article also highlights several aberrations or artifacts that may arise during the process of obtaining and processing images in MRI, and in each case demonstrates how the Fourier Transform is key to understanding and mitigating these issues. Among the artifacts discussed is the zipper artifact, which results from radiofrequency leakage and manifests as thin bright lines in the frequency encoding direction. Another is the Gibbs artifact, a manifestation of the lack of high spatial frequencies needed to approximate sharp edges within an image; and aliasing, which occurs when spin systems excited outside the field of view are erroneously superimposed in image space due to a phase shift of exactly 360 degrees.

Furthermore, the work discusses chemical shift artifacts that arise from the difference in resonance frequencies between protons in fat and water within the human body. This results in incorrect spatial assignment for signals originating from the same voxel, creating noticeable margins between fat and water interfaces.

Finally, the article emphasizes the importance of a solid understanding of the Fourier Transform in current medical practice, especially in MRI, not only for efficient image acquisition but also for accurate interpretation of images and identification of potential artifacts that could impact diagnoses.