Why Not Use the IFRAO SCALE in Rock Art. Part 2

0
1073

The well-known IFRAO color scale has become in recent decades a standard for the documentation of archaeological heritage, with special emphasis on the documentation of rock art.

However, despite its widespread use, its advantages today are more than questionable as it challenges a good number of fundamental criteria of colorimetry, whether from the point of view of color management or color correction.

A few months ago I had written a previous article citing the conceptual problems encompassed by the use of this chart, as well as some historical notes on its development. In this case, I will limit myself to quantifying the potential colorimetric errors if we intend to make any kind of adjustment based on this chart, or simply if we aspire that its presence in our scene serves as evidence for the correct documentation of color.

The printing

The IFRAO color chart is designed to be printed by each professional using their own means; this situation obviously creates significant inconsistency between each printed chart. This is because each printer has its own color space, or if we want to see it another way, its own way of interpreting initial RGB values, which is why every time we print something, the colors shown to us bear a relative resemblance to those viewed on screen.

In the original document containing the drawing of this chart, certain RGB values are specified that supposedly correspond to the color and neutral patches; however, here we face a conceptual problem, since RGB values need to be expressed in a color space to be understood, whether sRGB, Adobe RGB, Prophoto RGB, etc., or the space of a particular device. Perhaps here the reader should familiarize themselves with another article on this website called “Documenting digital color” to delve deeper into the concept of dependent and independent color spaces.

To be able to make delta-e estimates and quantify how different the color is between various supports or media, we need to work in the CIELAB color space, so the theoretical conversion from RGB to CIELAB is done using the sRGB standard; in this way, I deduce the theoretical values of the IFRAO color scale in CIELAB to have a reference with which to compare the quality of my print. These data are summarized in the following table:

Proposed RGB Theoretical CIELAB (sRGB) Measured CIELAB Differences
R G B L a b L a b CIEDE00 CIE76
White* 255 255 255 99 0,019 -0,019 92,98 0,46 -3,6 5,03 7,62
Gray 128 128 128 53,58 -0,01 57,16 2,66 -0,69 4,72 4,47
Black 10,8 1,96 -0,33 6,16 10,05
Red 214 39 45,74 71,19 45,08 48,21 67,87 43,02 3,07 5,39
Yellow 255 215 87,46 2,92 86,55 81,79 3,22 79,75 4,31 9,27
Green 134 73 48,87 -43,66 23,66 37,68 -48,11 19,52 10,47 12,73
Blue 50 90 11,46 36,26 -41,95 23 22,49 -35,87 10,06 19,39
Average 6,26 9,84

*The White values were not proposed by Bednarik. I have introduced this theoretical white by contrast with black. Although obviously this white depends on the paper white, it is significant to me to complete the error estimates.

These calculations can be deduced, for example, with the ICCTRANS tool from Little CMS or ICCLU from ArgyllCMS. In the case of using ICCTRANS, the command line would be as follows:

icctrans -v -i sRGB_Color_Space_Profile.icc -o *Lab

Among the RGB values and the theoretical CIELAB values for my printed IFRAO scale, I made a delta-e error for CIE76 of 9.8. For the reader to have a reference for this result, an approximate value of 3 indicates that two colors are similar, and from 5 two colors are noticeably different, with ISO 12647-2 considering any value above 5 as unacceptable. Therefore, my color chart is outside the acceptable thresholds of printing processes. Obviously, these results could be improved with proper color management; however, since the IFRAO and Bednarik documents speak little or nothing about it, I did not apply such techniques.

If we want, we can also deduce the RGB values from the measured CIELAB values to compare them with the proposed RGB; this is an unusual strategy but can be illustrative of the deviations caused by the lack of print control, or even regarding the paper white:

Proposed RGB Measured RGB (sRGB)
R G B R’ G’ B’
White 255 255 255 233 236 242
Gray 128 128 128 139 138 138
Black 32 29 30
Red 214 39 203 46 48
Yellow 255 215 237 193
Green 134 73 108 48
Blue 50 90 58 51 111

With this simple calculation, it becomes clear that each printed chart has unpredictable colorimetry, so under no circumstances can such a chart serve as a colorimetric reference if we have not taken the precaution of documenting the CIELAB or XYZ values, failing which, of our chart. This is a very common problem, which also happens with Kodak Q13 charts, which, lacking a known colorimetry, makes it impossible to deduce the colorimetric deviations of the image in the future or in quality control processes. Knowing the RGB values of a document is completely irrelevant, since when printed, those colors are represented in the color space of the printing device; not knowing how these transformations were made either, the result is a color scale without a known colorimetric reference even knowing the initial RGB values.

The visual density

Another value proposed by Bednarik is the visual density of the neutral patches. In my print, they coincidentally fit quite well, although depending on the brightness of the paper or inks, the visual density can vary considerably.

Density Proposed Obtained
White 0,08
Gray 0,7 0,6
Black 1,6 1,9

Spectral uniformity

One of the purposes or supposed benefits proposed for this color scale, regarding color correction, is to use its neutral gray patch as an instrument to perform white balances; however, this is another recommendation resulting from a certain lack of knowledge of the fundamentals of gray chart design.

A truly neutral gray must be a surface whose reflected spectrum is perfectly uniform throughout the entire visible spectrum. To perform this evaluation, a spectrophotometer is used so that spectral values are represented in an SPD (Spectral Power Distribution) graph. In another article “Spectral evaluation of gray charts” I delved into the details of the spectral aspects of this type of charts. But in general, observing the image on the left, where the neutral gray of my IFRAO scale made by laser printing (in orange) is compared with the D4 patch of my Colorchecker with a similar visual density of 0.72 (in blue). As can be seen, the neutral of the IFRAO scale shows no spectral uniformity; this is because most grays in inkjet or laser are formed by a combination of several dyes. However, the reader can observe that the sRGB values of my chart for the mid gray are: 139 138 138, so a quite optimal balance of the RGB channels can be observed, so a priori, it should not provide inconsistent results when performing a white balance.

However, this is not always the case; the problem of lack of spectral uniformity on a surface generates anomalous behaviors depending on the light source. It should be remembered that the produced color is the result of the light reflected by a surface, so frequently, these apparently neutral patches end up generating significant color casts depending on the nature of the light source under which they are observed, even though our spectrophotometer and calculations give us a good RGB or CIELAB value.

Conclusions

graphic documentation of heritageAlthough we could find certain benefits in this chart, related to its dimensional reference, and in a way we could risk neutralizing casts on the mid gray patch, the absence of known colorimetry in the IFRAO scales used over these decades unfortunately provides us with nothing more than a vague colorimetric relationship in the case of images with strong casts, assuming that the mid gray patch may be relatively well printed. Unfortunately, the low colorimetric precision provided by the general practice of mere white balancing, and in particular white balances on spectrally non-uniform color samples, gives us a vague trace of the alterations of patinas or pigments over time.

The documentation of color on heritage assets, or rock art in particular, demands more sensible methodologies, with workflows associated with color management, characterization of input devices, and design of transformation routines that help us record color more faithfully, so that it can constitute genuine evidence of the passage of time on a Cultural Asset.

You can find more information in the article: From the IFRAO Standard Scale to ICC: color as a preservation attribute in rock art documentation