Ultraviolet Photography: From Forensics to Art Inspection

0
4928

The expression “ultraviolet photography” is frequently used to describe very different techniques. Under this denomination, procedures that record UV radiation reflected by an object, systems that document visible fluorescence induced by UV, or, more broadly, multiband workflows combining independent acquisitions made in visible, infrared, and ultraviolet can be grouped.

The distinction is not only terminological. Each technique requires its own lighting, camera configuration, filtering, and interpretation criteria. Confusing them easily leads to erroneous conclusions, especially when applied to historical documents, works of art, or objects of forensic interest.

UV Reflectance and UV-Induced Fluorescence

Ultraviolet reflectance records the UV radiation that, after illuminating an object, is reflected by its surface and reaches the camera. To obtain this type of image, it is not enough to illuminate with a UV lamp: it is necessary that the source emits in the interval of interest, that the optics and sensor transmit or record such radiation, and that the filtering sufficiently blocks contributions of visible and infrared light.

Visible fluorescence induced by UV describes a different phenomenon. In this case, the object receives ultraviolet radiation and certain materials absorb part of that energy to emit light at longer wavelengths, usually within the visible spectrum. The camera does not record the UV radiation emitted by the lamp, but the visible luminescence produced by the material.

The difference has practical consequences. In UV-induced fluorescence it is common to work with a conventional camera, a UV source filtered to reduce its visible emission, and a barrier filter on the camera that prevents the passage of reflected UV radiation. In UV reflectance, on the other hand, a modified or specialized camera, optics sufficiently transmissive in UV, and a bandpass filter isolating the desired ultraviolet region are required.

In conservation, it is advisable to name the techniques precisely. The Library of Congress, for example, separates in its protocols visible fluorescence induced by UVA and UVA reflected photography.

The Ultraviolet Spectrum

Ultraviolet radiation is invisible to human vision and is located below the violet limit of the visible spectrum, approximately 400 nm. Generally, it is classified into three regions:

  • UVA: 315–400 nm.
  • UVB: 280–315 nm.
  • UVC: 100–280 nm.

In technical photography, conservation, and heritage documentation, work almost always focuses on UVA. Sources centered around 365 nm are common to induce visible fluorescence and can also be used, under a different configuration, in UVA reflected photography.

UVB and UVC should not be presented as ordinary extensions of work with UVA. They require much more specific materials, optics, filters, sources, and safety measures. Furthermore, UVC radiation from the Sun does not reach the Earth’s surface; human exposure to UVC comes from artificial sources.

It is also incorrect to state that UV or IR are monochromatic radiations. They are spectral regions that can contain a wide range of wavelengths. They lack color perceived by the human eye, but that does not make them monochromatic. When a UV or IR image appears colored, it is usually a false-color representation, created by channel assignment or data processing.

Applications in Document Examination and Heritage

Visible fluorescence induced by UV has an established application in document examination. Papers with optical brighteners, security fibers, inks, markers, and certain coatings can present fluorescent responses useful for differentiating materials, verifying security elements, or locating subsequent interventions.

Documento de identidad examinado con iluminación ultravioleta
UV-induced fluorescence can reveal security elements and material differences in documents.

However, a fluorescent response does not unequivocally identify a substance. The intensity and apparent color of the emission depend on the excitation source, the spectral sensitivity of the camera, filtering, exposure, and processing configuration. A fluorescence photograph can be valuable evidence but must be interpreted alongside other observations and material information of the object.

In art conservation, UV-induced fluorescence is frequently used to examine varnishes, overpaints, retouched areas, adhesives, and certain restoration products. It can help locate behavioral differences between areas of a painting but should not be considered conclusive proof of authorship, dating, or material nature. The same type of varnish can respond differently depending on its aging, thickness, dirt, or previous treatment.

Imagen de una pintura con áreas de repinte visibles bajo iluminación ultravioleta
UV fluorescence can help locate areas with different responses, such as varnishes or subsequent interventions.

UV reflectance offers another kind of information. As a surface technique, it can contribute to differentiating materials, residues, varnishes, pigments, or alterations present in the outermost layer. Its capacity to show information from underlying layers is limited: varnishes and other coatings can strongly attenuate UV radiation, and the response depends on the object’s composition and the spectral band used.

Visible fluorescence induced by UV and UV reflectance can be part of the same multimodal study, just like infrared reflectance or visible imaging. The important thing is that each acquisition is performed and documented as an independent modality. They should not be combined as if measuring the same physical phenomenon.

Camera, Optics, and Filtering

The first difficulty of UV reflectance is that most conventional digital cameras incorporate internal filters that block UV and IR. These filters help the camera reproduce the visible image more stably but reduce or eliminate the useful response in ultraviolet.

Cámara modificada para la captura de regiones no visibles del espectro
Capturing reflected UV requires that the camera, optics, and filters transmit the spectral region of interest.

A full-spectrum modified camera alone does not solve the problem. It is also necessary to consider the transmission of the optics. Many optical glasses, cements, coatings, and multilayer treatments attenuate UV radiation, especially as the wavelength decreases. The number of optical elements, their composition, and treatments can have more influence than the commercial name or the age of a lens.

In UV it is common to find focus shifts derived from chromatic aberration. A scene focused in visible may not remain focused in UV. For this reason, the focusing procedure must be verified with the final lighting and filtering configuration, especially in close-up photography, documentary reproduction, or work with reduced depth of field.

Filtering should be described based on its transmission curve. Commercial names alone do not indicate whether a filter sufficiently blocks visible and infrared or transmits the desired UV region. For UVA reflected photography, bandpass filters suitable for the complete system response are needed; for visible fluorescence induced by UV, it is necessary to avoid, as much as possible, excitation radiation reaching the sensor.

Comparación de la transmisión espectral de filtros para fotografía ultravioleta
The choice of filtering must be based on transmission curves and the spectral response of the complete system.

Lighting

Sunlight contains a relevant amount of UVA and a fraction of UVB, but its composition varies with time, season, altitude, latitude, cloudiness, and atmospheric conditions. It can be useful for exploratory observations, although it is not a controlled or easily reproducible source.

In documentary work, it is preferable to use a source whose spectral distribution is known. Lamps centered around 365 nm are common to induce visible fluorescence, but their quality and residual visible emission can vary. That residual visible emission must be controlled when intending to document fluorescence only.

Lámpara de luz negra utilizada como fuente de UVA
Sources centered around 365 nm are common to induce visible fluorescence, although their emission must be characterized.

High-intensity sources, including certain modified flashes, discharge lamps, or UVC sources, should not be used without spectral characterization, irradiance control, and an appropriate safety protocol. Modifying commercial equipment can alter its original optical protection and significantly increase the risk for the operator and the documented object.

Documents, Manuscripts, and Minerals

In historical documents, the response under UV can provide contrast between inks, supports, optical brighteners, adhesives, restorations, and contaminants. In the case of iron gall inks, for example, useful differences may appear compared to the support, although that response depends on the ink formulation, its state of alteration, the type of paper or parchment, and the technique used.

Pergamino manuscrito examinado mediante una técnica de imagen ultravioleta
The UV response of inks and supports depends on their composition, conservation state, and capture method.

It is incorrect to assume that paper, cellulose, or parchment always have a low or uniform response in UV. Archival materials may contain fibers, sizings, brighteners, adhesives, restoration products, or chemical alterations that significantly modify reflectance and fluorescence.

Some minerals exhibit luminescence under UV and this response can be useful as an indication to guide identification. However, fluorescence should not be used as the sole criterion: impurities, activators, inclusions, and conservation state can modify the response of the same mineral. UV observation should be integrated, when necessary, with complementary mineralogical or spectroscopic analyses.

Safety

UV radiation must be treated as a work hazard, not just a photographic resource. Exposure can affect skin and eyes, and the risk depends on wavelength, source irradiance, distance, exposure time, and workspace conditions.

Eye protection must be selected according to the source used and the spectral region it emits. Orange glasses can improve fluorescence observation by reducing visible blue light, but they do not by themselves demonstrate sufficient protection against UV radiation. Protective equipment must have transmission specification and optical density for the working range.

In addition to eye protection, exposure time, distance to the source, shielding, skin protection, and access to the work area must be controlled. A strong UV source should never be observed directly. UVC sources require special caution: they can cause eye injuries and skin burns after brief exposures.

Documenting the Procedure

Every UV image intended for conservation, forensic, or research purposes should retain sufficient information to interpret the result:

  • Exact modality: UV reflectance, visible fluorescence induced by UV, or other.
  • Illumination source, dominant wavelength, and filtering used.
  • Camera, modification performed, optics, and filters installed.
  • Distance, lighting geometry, and environmental conditions.
  • Exposure, sensitivity, aperture, and processing applied.
  • Visible references, scales, or patterns used, when appropriate.

UV photography can reveal information difficult to observe in visible light, but it does not replace material analysis nor turn an isolated observation into a definitive conclusion. Its greatest value appears when it is part of a coherent, repeatable, and properly documented protocol.

References