The resolution aspects of our digital equipment are another of those hot topics that lend themselves so well to commercial comparisons between devices, and which certain websites or authors like to delve into superficially and often subjectively, for the covert promotion of equipment and commercial brands.
Resolution is a concept intimately related to the degree of detail that can be perceived in an image, and which obviously has a direct relationship with the Pixels Per Inch (PPI) of an image, and ultimately with the megapixels of our equipment; however, stopping at this statement may not always be convenient, so it is better to delve a little deeper into the factors that condition the resolution of an image.
When we talk about resolution, we must inherently talk about contrast, since below 5% contrast we stop perceiving detail. For our purposes, we can define contrast as “the difference in tone with which a pair of lines, white and black respectively, is perceived or recorded.” Therefore, the greater the contrast, the greater the sensation of resolution. This degree of contrast is measured in terms of what is known as acutance, which is nothing more than the speed at which one density level transitions to another, and which helps us understand the edges between high contrast areas, so that if between two black lines there is a gray area, we would be talking about poor acutance since the transition between zones has been smooth.
There are numerous processes by which the acutance of a sensor can be evaluated; on one hand, there is the MTF strategy, which I already explored in the article “Calculation of the MTF with ImageJ“, but another very simple one is the use of line pair charts, or simply approaching the theoretical resolution through the Nyquist theorem, which indicates that the sampling rate must be twice the highest frequency component.
The theoretical maximum resolution, expressed in sampling frequency in line pairs per millimeter (Lp/mm), or what we can also describe as Nyquist frequency, is given by the following equation:
Nf (lp/mm) = 1 / ((Sensor width mm / Number of pixels in width)*2)
We must talk about theoretical resolution because sensors are accompanied by a high-pass or anti-aliasing filter that conditions these calculations, which end up being too optimistic, but significant enough to clarify some concepts.
In this way, we can perform the following calculations based on two devices:
On one hand, a Nikon D700 with a Full Frame sensor (Full Format) of 36×23.9mm and a matrix of 4256×2832 pixels. And a Nikon D300 with an APS-C sensor, of 23.6×15.8mm and a matrix of 4288×2848 pixels. Remember to the reader that a Full Frame sensor is one that has the dimensions of the classic 35mm photo-chemical film, while the APS-C (Advanced Photo System Classic) is the most common sensor size among DSLR cameras (Digital-SLR).
If we apply the previous formula, we will find that our Nikon D700 theoretically has 59 Lp/mm and our D300 90 Lp/mm, which paradoxically means that the D300 with an APS-C sensor has more resolution than our D700 Full Frame. This is easy to understand since simply by eye, we can see that both devices have practically the same number of pixels for different sensor sizes, so our Full Frame device has a lower pixel density.
What advantage then does a device with a Full-Frame sensor have over an APS-C?
Well, on one hand, we have the magnification factor: if we want to make a print of 203x254mm, from a Full Frame sensor we will have to enlarge the image produced by the sensor 7.5 times, and from an APS-C sensor we will have to enlarge it 11.3 times to reach those dimensions, so the greater the magnification factor, the more the degree of detail in our final copy will be affected.
Another advantage of Full Frame sensors is their greater depth of field. This is a highly relevant situation for certain types of photography. For example, in digitization work with reproduction tables, since focusing distances are usually minimal, in the reproduction of objects or documents with some volume, depth of field can be a critical factor in the sharpness of certain areas of the image. In general, in any close-up photography where depth of field tends to be more critical.
The reason why a Full Frame sensor has greater depth of field than an APS-C one is related to the size of the Circle of Confusion (CoC), which is the maximum size of the Airy disk so that once magnified the human eye perceives it as a point, so that any point equal to or smaller than the CoC will be perceived as sharp areas. The Airy disks are formed by the presence of the diaphragm in our optics and their diameter is related to its aperture. As we will see later, the depth of field equation involves multiple factors; however, under equal conditions, the larger the circle of confusion, the greater the depth of field.
By introducing the CoC definition, we again encounter a concept we have already addressed, which is the magnification factor of the image from the sensor to the observation format, so there is an intimate relationship between the circles of confusion and the sensor size.
To better understand the CoC and its relationship with sensor size, let’s delve into its calculations:
The real resolution of an estimated enlargement in Lp/mm is given by the formula:
R = Rf (enlargement diagonal / sensor diagonal)
Where Rf is the resolution in Lp/mm of our enlargement assuming that the maximum resolution of the human eye (at 25cm observation) is estimated at 5-6 Lp/mm while the average is between 3-4 Lp/mm.
Thus, for an enlargement of 203x254mm with a diagonal of 325mm using a Full Frame sensor with a diagonal of 43mm, we will have for a viewing resolution of 4 Lp/mm:
R = 4 * ( 325 / 43 ) = 30.2 Lp/mm
To find the CoC in mm we calculate the inverse:
CoC = 1 / R = 0.033 mm
In fact, 0.03 mm is the standard size for 35mm.
If, on the other hand, we do the same calculation with an APS-C sensor with a diagonal of 28mm, we have:
R = 4 * (325 / 28) = 46.4 Lp/mm CoC = 1 / 46.4 = 0.021mm
Where we observe how 0.02 is usually the CoC of most APS-C sensors.
With this concept clear, if we look at the table of Airy disk diameters by aperture or f-number, we can observe something very curious: for an APS sensor from an aperture of f/11 the disk diameter is greater than the circle of confusion, so we are losing sharpness. And coincidentally, we see how the maximum value of the circle of confusion corresponds to the CoC value for a Full Frame sensor; this is because 0.03 is the standard for 35mm (and an enlargement to 203x254mm at a resolution of 4 Lp/mm), where we can use apertures of f/22.
| Aperture | Airy disk diameter (mm) |
|---|---|
| f/1 | 0,0013 |
| f/1.4 | 0,0019 |
| f/2 | 0,0027 |
| f/2.8 | 0,0038 |
| f/4 | 0,0054 |
| f/5.6 | 0,0075 |
| f/8 | 0,0107 |
| f/11 | 0,0148 |
| f/16 | 0,0215 |
| f/22 | 0,0295 |
If the values obtained for the circles of confusion for a Full Frame or APS sensor in the depth of field (DoF) formula:
DoF = (2*c*F2*D*fn*(F- D))/((F2 - c*F*fn + c*D*fn)*(F2 + c*F*fn - c*D*fn))
Where F is the focal length, D the focusing distance (in meters), CoC the circle of confusion (in microns), and fn the aperture of our diaphragm.
Therefore, for a focusing distance of 0.45m, an aperture of 11, and a focal length of 50mm, we should obtain a depth of field of 3cm for an APS-C sensor and 5cm for a Full Frame.
As we see, a Full Frame sensor has certain advantages over an APS-C; however, it is not possible to state that one system is better than the other, as always, everything will depend on the final purpose of our work.
However, as we said at the beginning, calculations regarding the resolution of a device based on Line Pairs per mm not only depend on the size or density of the pixels of a sensor, but obviously the combination of sensor plus lenses plus the anti-aliasing filters that our device carries will condition the final resolution, a topic I will address in another article.
You can experiment with these calculations with the Circle of Confusion and Depth of Field Calculator