Recently, in some tests we had to carry out, we needed to attenuate the luminous intensity of a standardized light box in order to recreate certain viewing conditions.
Since we are working with standardized light with a high CRI, the premise was obviously not to alter these conditions as much as possible, so we resorted to installing a series of neutral density (ND) filters in the light box, in the form of stackable sheets, well known to anyone initiated in the world of photography, in order to reduce its intensity to the required level.
In order to validate our working environment as much as possible, we conducted a small evaluation of the new lighting conditions to assess possible deviations in the quality of the illumination.
For this, we used two one-stop attenuation filters, aiming to sum two stops by stacking them on the spectrophotometer.
The results, although sufficient within our working framework since we do not need to reach certain attenuation limits, are slightly concerning if we intend to use this type of filter in situations where optimal color reproduction is required, such as artifact digitization projects.
The results can be described in the following table, where deviations caused both at the level of color temperature and CRI can be seen, reaching unacceptable limits for the simultaneous use of two one-stop ND filters.
| Filter | Lux | EV | Temperature | CRI |
|---|---|---|---|---|
| No filter | 566.2 | 7.8 | 5034K | 85.8 |
| + 1ND | 253.2 | 6.7 | 5128K | 81.7 |
| + 1ND + 1ND | 116.4 | 5.5 | 5226K | 77.7 |
Another way to review what is happening is to use a spectral power distribution (SPD) graph, shown at the beginning of the article, where it is easy to observe the decrease in intensity when interposing the different filters.
However, in this SPD graph, the alteration of the spectrum may not be especially evident. Therefore, if we roughly scale both graphs, we can easily evidence a certain variation in the spectral distribution around the wavelengths of 500nm, approximately coinciding with the cyan region, and around 600nm, approximately coinciding with the reds. This situation causes the decrease in CRI and the use of neutral density filters.
It can be observed together with the previous table that there has been a slight variation in color temperature, cooling down a bit, possibly due to the decrease in energy in the red region of the spectrum while maintaining the blue region.
However, it is possible to observe that certain regions coinciding with greens and blues hardly experience any variations. Ideally, although having distributions with relatively lower energy, the distribution along the spectrum should be proportional for each region.
Using a 2-stop filter instead of two 1-stop filters represents an improvement in results, as less support surface is interposed. However, attention must be paid to the use of these filters in situations or projects where high color reliability indices are required.
On the other hand, it is very likely that this situation can be extrapolated to the use of this type of filter in photography, so in the absence of more time to delve into the subject, we should be especially cautious in the use of this type of filter.