Light sources in color reproduction

0
1122

Light is one of the essential elements for color to occur. However, frequently when we talk about light sources, the concept that most quickly comes to mind in the discussion is color temperature, perhaps because it is the most anchored in photographic language as well as being the most evident.

However, there are other factors perhaps more significant than color temperature itself, such as the Color Rendering Index or the UV content of a light source.

Color Rendering Index (CRI)

The concept of CRI arises from the need to establish a metric that informs us about the ability of a light source to reproduce color, which began to be considered with the development of the first artificial light sources.

The calculation of CRI, although there are various strategies, starts from the reference to an illuminant with ideal reproduction, such as sunlight, which after all is an incandescent body. From this ideal comparison, a scale from 0 to 100 has been developed, where 100 would be the ideal of color reproduction, usually only achievable by sunlight on clear days.

The ability to reproduce color by different light sources is based on the nature of the energy they emit. The study of the “quality” of the spectrum of a light source is carried out through the well-known SPD (Spectral Power Distribution) graphs that often accompany many lamps of certain quality. In this way, incandescent bodies tend to produce continuous spectra, perhaps with marked dominants towards the blue region or the red region. However, other light sources, such as fluorescent or vapor sources, tend to produce discrete spectra characterized by the formation of bands which causes an uneven distribution of energy reaching a surface.

The issue of CRI has generated significant research to achieve lamps that, even coming from technologies with discrete spectra, achieve a high CRI. The strategy has often been to adjust the bands of the visible spectrum to the human observer model, and although there are areas of the spectrum devoid of information, since they are outside our spectral sensitivity, they are less involved in how color is perceived.

Normally, in reproduction and copy verification matters, we must always work above a CRI of 90.

Color temperature

When we talk about color temperature and light sources, perhaps the most appropriate term is Correlated Color Temperature (CCT), or in other words, the color with which we perceive a light source in relation to the Planckian scale of Kelvin degrees (2000ºK=Red; 6000ºK=Blue, etc…).

Therefore, color temperature is that scale which quantifies what we would psychologically define as “Warm Light” or “Cool Light.”

The problem with electronic devices is that they do not experience what we know as chromatic adaptation, by which humans can perceive white as such under any color temperature, whereas electronic devices must be informed where to set their white point so that they reproduce white as such.

Unfortunately, the light sources with the best CRI are incandescent, with a CCT around 2500ºK, which translates into sources with a yellow-reddish hue, making them unsuitable for reproduction and inspection purposes.

UV content

Another issue that is not often discussed is the UV content of a light source. This may or may not be significant depending on the materials we are working with. In other articles (“Fluorescent Whitening Agents in color reproduction“) I discussed the presence of whitening agents (Fluorescent Whitening Agents, FWA) which compensate for the yellow of cellulose by introducing a blue matrix in the paper caused by fluorescence under UV.

This small detail implies that if we observe or reproduce certain papers under light sources poor in UV, the response will be different than if we do so with UV-containing sources.

Therefore, one must be very cautious with this aspect, as the appearance of a copy, depending on the paper quality, can change significantly independently of the CRI or CCT under which it is observed or photographed.

Characterization of light sources: determining UV content

The calculation of the UV content of a light source can be done precisely by taking advantage of the presence of fluorescent agents in most low-quality papers. For its calculation, we can use the Illumread tool from ArgyllCMS.

Illumread is designed for a workflow where, from various measurements, the UV content of a light source is inferred.

The operating principle is based on several phases; as an example, in each phase we will measure a different source: daylight, a tungsten bulb, and a standardized light lamp such as Grafilite.

  1. We directly measure a light source (Step 1)
  2. Next, we measure its light reflected through a paper rich in FWA (Step 2)
  3. Then directly measure the paper (Step 3) at this point attention must be paid to the fact that we are using the device’s own illumination source which is usually UV cut (Be careful because not all spectrophotometers are “UV Cut”).
  4. Finally, with Step 6, we compute all values, and by difference between UV and UV Cut measurements, we deduce the amount of UV in a light source.
Daylight Normalized GrafiLite Light Tungsten
Step 1
Step 2
Step 3
Step 6
UV 2.08 0.22 0.02

It should be noted that the Grafilite lamp has a certain UV component, which is interesting when working with papers containing FWA, as the results will be closer to reality.

Characterization of CRI and CCT

Another simpler process is to determine the CRI and CCT of a light source. This process can be done with the Spotread tool from ArgyllCMS. For this, we use the command line:

spotread -S -a

Where -S prints the SPD graph if needed, and -a sets the measurement to ambient mode.

Among the data we can extract from Spotread are:

  • The amount of ambient light measured in Lux.
  • The CCT, or correlated color temperature
  • The Planckian Color Temperature
  • The Ambient Color Temperature
  • The Color Rendering Index.
  • It even provides EV (Exposure Values) for 100 ISO

As we can see, we have up to 3 measurements of color temperature, which although will yield very close values, we must pay attention to which scale or reference they belong.

Thus, for the examined light sources, we have the following results:

Daylight GrafiLite Tungsten
CCT 10590K 5220K 2646K
CRI 98.7 91.0 98.3

Normalized Light?

“Normalized light” are neither better nor worse light sources; they simply try to standardize the visualization and reproduction of color towards standard lighting conditions in order to obtain consistent and coherent results.

It is not possible to talk about color without intrinsically referring to lighting conditions. Whether we are talking about monitor calibrations, evaluation of printed copies, or reproduction of originals, the light sources used are as critical as any other factor in our workflow.