History of the Kodak Q13 Color Separation Guide
The Q-13 Color Separation Guide, or Q-14 in its larger version, was introduced by Kodak around the 1970s as a tool for subjective evaluation in color separation processes in offset printing. Hence the nickname ‘color separation guide’.
The Kodak Q-13 are no longer originally manufactured by that company, but by Tiffen and other companies, always under similar standards.
Behind the Q-13 designation, two charts are supplied: one composed of two rows of nine patches (color bars) with the primary colors RGB and CMYK at different saturation levels according to the row; and a grayscale composed of 20 zones with optical densities ranging from 0.05 to 1.95 in steps of 0.1. Both charts are printed on semi-glossy paper, therefore slightly shiny, a factor that gave it certain advantages over its contemporary the ColorChecker which, with its matte finish, reaches a maximum visual density (Dmax) of 1.5.
The Q-13 have been quickly transferred from the Offset world to photographic processes and have found their niche in various fields and strategies of image analysis and calibration. One of them, where they are perhaps most common, are digitization or registration processes of documents, artworks, archaeological objects, etc.; as an attempt to offer help to record color as faithfully as possible.
The Kodak Q13 in digital imaging

However, in the full development of the digital imaging world, the use of these charts begins to lose relevance compared to the world of color management and the ability to create ICC color profiles that approximate the color of an image to reality. It should be noted that this pair of charts, unlike the Colorchecker, have never had a standardized or constant color production, so each batch of charts that comes to market has its own color values. This fact, along with the limited palette of patches they offer, makes them unfeasible, or not recommended for processes related to color management.
However, the Q-13 grayscale chart helps us and reinforces the use of other charts more suitable for color management such as the Colorchecker or the IT8. Or in any case, due to their lower cost, they are an alternative to more expensive charts.
The Q-13 grayscale can be useful for studying the dynamic range of a capture device, or for noise studies. But perhaps what it can help us most with is precise color and exposure correction of an image.
How to adjust an image with a Q-13 grayscale?
A calibration with this type of chart will have a result that affects both exposure and neutralization of color casts. This is due to the possibility of balancing the RGB channels to avoid dominance of some over others and at the same time raise these values towards a certain standard or canon.
Since we are working with gray patches, these must have the same value for each R, G, and B channel; so if we observe significant differences between the values of each channel we must understand that our image is affected by a color cast.
Similarly, since it is a gradation from white to black, we must be able to extract RGB values for each patch. Logically, white should be 255-255-255 and black 0-0-0. However, this approximation is not entirely accurate, since we are talking about values measured on papers and inks, so we will hardly reach these values. This phenomenon means that if we tried to make an adjustment using the gray, white, or black point sampling tools included in curves or levels in PS, we would face a somewhat unrealistic situation, since white would be pushed to 255 and black to 0.
Perhaps the best would be to make spectral measurements of each patch and then try to bring our image to those values. However, there are some standard values that can give us clues about what values we should handle to adjust an image correctly. For example, Fred Miranda proposes the following values for white: 255 for specular or bright white, 250 for white papers, 240 for textured white papers, 230 for shadows on solid white objects, and 220 for bright midtones.
Although this white data is a starting point, it falls short for calibration. To standardize discussions around gray patch values, the NARA (U.S National Archives and Records Administration) in the manual ‘Technical Guidelines for Digitizing Archival Materials for Electronic Access: Creation of Production Master Files’ proposed in 2004 a series of recommendations and suitable values for image calibration with the Q-13 grayscale chart.
| Neutral White Point (WP) | Neutral Midpoint (MP) | Neutral Black Point (BP) | Alternative Neutral Black Point | ||
|---|---|---|---|---|---|
| Steps and density | Q-13 | A | M | 19 | B |
| Visual Density | 0.05 to 0.10 | 0.75 to 0.85 | 1.95 to 2.05 | 1.65 to 1.75 | |
| Proposed Values (aimpoints) | RGB Levels | 242-242-242 | 104-104-104 | 12-12-12 | 24-24-24 |
| % Black | 5% | 59% | 95% | 91% | |
| Acceptable Margins | RGB Levels | 239 to 247 | 100 to 108 | 8 to 16 | 20 to 28 |
| % Black | 3% to 6% | 58% to 61% | 94% to 97% | 89% to 92% | |
These are the values proposed, or aimpoints, by NARA regarding document digitization; perhaps the reader can speculate with their own based on their experiences and needs.
Having the visual densities in the table above offers us the possibility to use these values with any other grayscale chart where visual density is expressed. We can calculate the Midpoint from patch 19 with the following formula: MP = WP – 0.60 (WP-BP) or from the alternative point B or patch 16 with the formula MP = WP-0.63 (WP-BP).
The 20 patches of the Q13 grey scale are organized under an alphanumeric numbering. The numerical values correspond to the visual densities of each patch, so patch 4 has a density of 0.4 and patch 14 has a density of 1.4. The letters accompanying patches 0, 7, and 16 correspond to the White Point, Midpoint, and the so-called Auxiliary Black Point, which was conceived to avoid using patch 19 for the Black Point, since due to the reflectance of the chart, highlights can occur on this patch and contaminate measurements.
| Patch | RGB | Density |
|---|---|---|
| 0(A) | 242 | 0,05 |
| 1 | 218 | 0,15 |
| 2 | 196 | 0,25 |
| 3 | 177 | 0,35 |
| 4 | 159 | 0,45 |
| 5 | 143 | 0,55 |
| 6 | 129 | 0,65 |
| 7(M) | 116 | 0,75 |
| 8 | 105 | 0,85 |
| 9 | 94 | 0,95 |
| 10 | 85 | 1,05 |
| 11 | 77 | 1,14 |
| 12 | 69 | 1,25 |
| 13 | 62 | 1,35 |
| 14 | 56 | 1,45 |
| 15 | 50 | 1,56 |
| 16(B) | 45 | 1,66 |
| 17 | 41 | 1,75 |
| 18 | 37 | 1,84 |
| 19 | 33 | 1,95 |
Theoretical values of the Kodak Q13 Grey Scale patches. The calculations of visual density from RGB values and vice versa can be downloaded in this Excel





Once the values we should have in the key patches of our Q13 are known, we can proceed to apply them to an image. For this, we use the curves tool in PS, preferably as an adjustment layer.
The working procedure with the curves tool is based on locating, per channel, the input and output values of the patch we want to treat. For this, we have several possibilities. One is the On-image adjustment tool, symbolized by a hand with arrows. This tool, once activated and clicking on the patch, will indicate its position on the curve and offer the possibility to modify its input and output values. Another option is to know the input values beforehand thanks to a color sample on the patch and clicking anywhere on the curves graph. Text boxes will activate where we can enter both the input value indicated by the color sample and the output value we want to include. This process must be done per patch and per channel. For readers unfamiliar with the curves tool and its adjustments, they can observe, in the info panel, the relationship between the RGB values of a color sample and the input and output values of the curves graph for a given color: the original value of a channel is called the input value and the value we want to assign to that channel is the output value. When we open the curves tool we see a slope instead of a curve, this is because all input values coincide with output values.
This adjustment process must be done for each patch A, M, B and for each channel R, G, and B. Once finished, if we intend to calibrate a series of images, we can save our curves adjustment to load it in subsequent images taken under the same circumstances.
If we have put this process into practice, we will have observed the tediousness of the task, especially if we face work with various captures of different nature. To facilitate this operation, I have written a small Photoshop preset that will allow us to adjust an image in a few seconds.
Q13 Grey Scale Calibrator
It is a preset, or Photoshop script of my own authorship, whose purpose is to create a curves adjustment layer that brings points A, M, B, and 19 of our grayscale to particular values, according to the method described above but in a single click.
Installation:
You can download Q13 Gray Scale Calibrator here.
NOTE: this JSX script is very old and may not work in modern versions of Adobe Photoshop. The download points to my old site which is not https, so a security alert may appear in the browser.
Q13GreyScaleCalibrator must be installed in the following directories depending on the operating system:
On Mac OS X:
/Applications/Adobe Photoshop CS4/Preset/Scripts
On Windows XP
\Program Files\Adobe\Adobe Photoshop CS4\Preset\Scripts
We must replace the CS version with the corresponding one: CS3, CS4, or CS5.
Once this step is completed, we must start or restart Photoshop.
We can access the preset through the File – Scripts menu
Usage
Its use is simple, just load an image in our PS that contains a Q13 grayscale chart and create 3 or 4 color samples according to the pattern:
- Sample 1 patch A
- Sample 2 patch M
- Sample 3 patch B
- Sample 4 patch 19, this sample being optional.
If both patch B and 19 have value 0, because the dynamic range does not extend beyond patch B, sample 19 is unnecessary and even counterproductive.
In most cases, the exclusive use of patches A, M, and B yields correct results. Only if we have an image with a very high dynamic range is it recommended to use patch 19.
Once the samples are located, we go to the File – Scripts – Q13GreyScaleCalibrator menu. In a few seconds we will have an adjustment layer with the calibration curves for our image.
If desired, we can save the established adjustment in the adjustment options menu to use it in other similar situations.


The script will bring the values of the key patches to those cited in the NARA table mentioned above. If we do not agree with those data, we can include our own by editing the script with a plain text editor and replacing the values of the outPutValues array with those we are interested in:
var outPutValues = new Array ;
outPutValues[1] = 242 // A
outPutValues[2] = 104 // M
outPutValues[3] = 24 // B
outPutValues[4] = 12 // 19
When we want to correct very aggressive color casts, it is ineffective to use the curves tool due to its limitations. It is preferable to perform a prior White Balance adjustment on our RAW developer and then refine it with Q13GreyScaleCalibrator.

Precautions
It is worth highlighting that throughout this article we have been talking about RGB values, which can lead to certain headaches if we are going to work simultaneously with color management, or in other words, with reassignments and conversions to different ICC color profiles. Every image we open in Photoshop will have an assigned color profile; this profile makes our image have a certain appearance regardless of the RGB values of our image, while a conversion will maintain the appearance but change the RGB values.
Therefore, it is advisable to perform these calibration processes of the white, mid, and black points after a conversion to a profile or working space. Otherwise, even if we perfectly calibrate our image according to the values described above, after conversion we will see how those adjustments fade, accumulating differences of up to 20% compared to the original calibration.